Expansion Tank

15 models · single & dual chamber · PP and SS304 · 1–14.5 L

Expansion tank family — single and dual chamber, PP and SS304
Expansion tank family — single and dual chamber, PP and SS304

Overview

A pressurised expansion tank for the coolant circuit of a fuel-cell system. It absorbs the volume change of the coolant between cold start and operating temperature, holds the system pressure, and gives the circuit a place for entrained gas to separate. Single- and dual-chamber bodies in PP or SS304, from 1 L to 14.5 L.

Key features

  • Sized on the loop — usable and expansion volumes quoted separately
  • Single or dual chamber — two independent circuits in one housing
  • PP for standard water-glycol coolant; SS304 where the circuit runs hot
  • Custom opening pressure and port arrangement on the SS304 range
  • 1311HF-SQ90L is the grade specified for hydrogen fuel-cell vehicles

Technical data

Model selection

ModelChamberTotal (L)Usable (L)Expansion (L)MaterialWorking temp.
1311-S1.6LSingle1.60.80.8PP−40~120 °C
1L+1LDual1.0+1.00.6+0.60.4+0.4PP−40~120 °C
1.7L+1.5LDual1.7+1.51.2+1.00.5+0.5PP−40~120 °C
1311HF-S20LSingle2.01.30.7PP−40~120 °C
1311HF-S35LSingle3.51.22.3PP−40~120 °C
4L+2.4LDual4.0+2.42.4+1.31.6+0.9PP−40~120 °C
1311HF-S40LSingle4.01.32.7PP−40~120 °C
1311HF-S47LSingle4.72.12.6PP−40~120 °C
1311HF-S90LSingle9.06.03.0PP−40~120 °C
1311HF-SQ90LSingle9.05.82.6PP−40~120 °C
1311HF-S150LSingle14.510.54.0PP−40~120 °C
1311HF-J20LSingle2.01.30.7SS304−40~120 °C
1311HF-J26LSingle2.61.70.5SS304−40~120 °C
1311HF-J4.5L+J9LDual4.5+9.03.0+3.01.5+6.0SS304−40~120 °C
1311HF-J13.5LSingle13.59.04.5SS304−40~120 °C

Total, usable and expansion volumes are listed separately. Choose on the usable and expansion volume the loop actually needs, then check that the body fits the space available. SS304 models allow the opening pressure and port layout to be customised.

Where it is used

Volume change — coolant expansion between cold fill and operating temperature

Gas separation — entrained air leaves the coolant before the pump

Pressure holding — the cap keeps the loop above coolant vapour pressure

From the engineering notes

Background on the design decisions behind this component — all articles.

Isolated DC-DC first, then the coolant piping

The 100 Ω/V and 500 Ω/V rules come from touch-safety limits, not from the converter. Worked numbers for a 500 V stack on an 800 V bus, and what they mean for hose length and rigid tube.

Expansion Tank — product brochure (PDF) Full specifications, model selection tables and engineering notes. Two pages, English.
Download PDF

Tell us what you are building

Send us your power rating, input/output voltage and application. We reply with a model recommendation and lead time.