Fuel Cell Cooling Circulation Pump

Seal-less canned motor · 900–4500 W · 165–600 L/min

Seal-less canned motor cooling circulation pump
Seal-less canned motor cooling circulation pump

Overview

A seal-less canned-motor coolant pump for fuel-cell cooling circuits. Nine models from 900 W to 4500 W, rated up to 600 L/min at 32 m head, with CAN 2.0B control, multi-protection and an insulated medium design compatible with fuel-cell coolant.

Key features

  • Seal-less canned-motor design — zero leakage, no shaft seal to wear
  • Brushless PM motor with optimised hydraulics
  • CAN 2.0B real-time speed and fault feedback
  • Dry-run, locked-rotor, over-temperature and over-current protection
  • ≥ 15,000 h service life, low noise, IP67
  • Insulated medium design — wetted parts electrically insulated

Technical data

Model selection

ModelRated powerRated flow & headRated voltageMax. flowMax. headNoiseComm.Protection
EPH900L-00900 W165 L/min @ 15.2 m345 V DC210 L/min18.9 m≤ 60 dB(A)CAN 2.0BIP67
EPH900H-35≤ 900 W165 L/min @ 12.5 m410–750 V DC210 L/min18.9 m≤ 60 dB(A)CAN 2.0BIP67
EPH1500H-001500 W210 L/min @ 22 m550 V DC330 L/min27 m≤ 68 dB(A)CAN 2.0BIP67
EPH2500H-002500 W260 L/min @ 24 m550 V DC330 L/min30 m≤ 70 dB(A)CAN 2.0BIP67
EPH2500H-D42500 W360 L/min @ 17 m800 V DC400 L/min30 m≤ 70 dB(A)CAN 2.0BIP67
EPH2500H-952500 W260 L/min @ 24 m550 V DC330 L/min30 m≤ 70 dB(A)CAN 2.0BIP67
EPH2500H-C32500 WCustomCustomCustomCustom≤ 70 dB(A)CAN 2.0BIP67
EPH4500H-004500 W600 L/min @ 24 m550 V DC660 L/min32 m≤ 72 dB(A)CAN 2.0BIP67
EPH4500H-564500 WCustomized410–750 V DCCustomizedCustomized≤ 72 dB(A)CAN 2.0BIP67

EPH2500H-C3 and EPH4500H-56 offer customisable flow, head and voltage options. Select on the rated flow and head at the operating point, not on maximum values. Noise measured at 1 m.

Where it is used

Coolant circulation through stack, radiator and heat-exchanger loop

900 W and 1500 W models — passenger and light-commercial stacks

2500 W and 4500 W models — heavy-duty vehicles and stationary systems

Fits glycol- and water-based coolant loops without modification

From the engineering notes

Background on the design decisions behind this component — all articles.

Isolated DC-DC first, then the coolant piping

The 100 Ω/V and 500 Ω/V rules come from touch-safety limits, not from the converter. Worked numbers for a 500 V stack on an 800 V bus, and what they mean for hose length and rigid tube.

Fuel Cell Cooling Circulation Pump — product brochure (PDF) Full specifications, model selection tables and engineering notes. Two pages, English.
Download PDF

Tell us what you are building

Send us your power rating, input/output voltage and application. We reply with a model recommendation and lead time.